LED Constant Power Emergency Driver Lasting 3 Hours

- Automatic self-test function
- Status of the battery.
- Status of the LED
- Charge condition
- Duration test
- Functional test


DOWNLOAD: SPEC SHEET

Product Detail

Product Tags

- This constant power emergency driver provides

60-180 Minutes duration in the event of a power failure. Suit for LED luminaire with external driver 100W or below.

- Lithium iron phosphate Battery backup

IFR18650MUB 3.2V 1500mAh battery cell,

- Output: DC10-50V. 50-200V Constant power 2-6W

Dimension

led emergency driver2

-Automatic self-test function

-Status of the battery.

-Status of the LED

-Charge condition

-Duration test

-Functional test

Application

-LED Downlight, Tri-proof, Linear LED light fixture

Battery pack

led emergency driver3

There are three combinations of batteries. Please ask the service commissioner for the specifications.

Model

Output

Constant power

Battery backup

Duration
CK-7091L DC 10-50V 6W

LiFePO4 6.4V 1.5AH

1 hour
CK-7091H DC 50-200V 6W

LiFePO4 6.4V 1.5AH

1 hour
CK-7092L DC 10-50V 3W

LiFePO4 6.4V 1.5AH

2 hours
CK-7092H DC 50-200V 3W

LiFePO4 6.4V 1.5AH

2 hours
CK-7093L DC 10-50V 4W

LiFePO4 6.4V 1.5AH

1.5 hours
CK-7093H DC 50-200V 4W

LiFePO4 6.4V 1.5AH

1.5 hours
CK-7094L DC 10-50V 2W

LiFePO4 6.4V 1.5AH

3 hours
CK-7094H DC 50-200V 2W

LiFePO4 6.4V 1.5AH

3 hours
CK-7095L DC 10-50V 4W

LiFePO4 6.4V 3.0AH

3 hours
CK-7095H DC 50-200V 4W

LiFePO4 6.4V 3.0AH

3 hours

Automatic self-test function

LED status display

Color State
led emergency driver4 Red stable: charging mode
 led emergency driver5 Red flashing:Failure ad below

Battery is not connected Battery is defective

Load failure during emergency mode, open circuit/short circuit

Battery capacity abnormal

led emergency driver6 Green stable: battery fully charged
led emergency driver7 Red and Green off: discharging mode or mains supply disconnected

Functional test

Connecting battery firstly, connecting mains supply then, this emergency conversion module will automatically go into emergency mode and discharge for 3 seconds.

Timer stats to calculate when battery is fully charged for the very first time.

The emergency conversion module will automatically discharge 10 seconds every 30 days as a short time functional test.

Duration test

Emergency conversion module will automatically discharge 90 minutes every 180 days.

If a mains supply failure occurs at any time, before or during functional test and duration test period, emergency conversion module will go into emergency mode immediately. Timer would not re-calculate if battery is not disconnected after emergency mode. If the battery is disconnected, timer will re-calculate.

The test switch and indicator light are connected through a plug on the inverter.

Our Factory

asdada (1) asdada (2) asdada (3)
asdada (4) asdada (5) asdada (6)

Our Exhibition

asdad1 asdad2
asdad3 asdad4

Our Certificate

Certification

 


  • Previous:
  • Next:

  • Write your message here and send it to us
    Whatsapp
    Send an Email